The 4 deringer 20g is designed for fire protection and waterworks applications. Claval back flow preventers are primarily used in potable water for the health and comfort of the crew. Stocking all major brands including watts, ames, febco, conbraco, wilkins, hersey, flomatic, midwest and more. Bronze double check valve assemblies with gear operated slow close. Double check valve backflow prevention assembly for assemblies 3 thru 10 pdf.
Encapsulated solenoid with captive plunger used on every hunter valve provides hasslefree service. Three ball valves for the connection of a differential pressure gauge. Other products make reference to a vacuum break, i dont know the difference, but i can say that. We offer the largest selection of backflow prevention solutions for any application. It consists of stainless steel body construction with internal rubber components and is designed for continuous or. Chapter 4 backflow prevention assemblies and devices. It is a contractor favorite, providing a variety of residential and commercial customers with extreme stability, ruggedness, and ease of repair for more than 40 years. Double check valve assembly backflow preventers are often found on water lines servicing fire sprinkler systems, commercial swimming pools, water treatment tanks, to name a few. Db pipe interrupter with atmospheric vent and moving element. Upstream of the backflow preventer is mandatory to install a strainer 577 series. To learn more, download our new marine products brochure. Choose, install and register a backflow prevention device suitable for your risk rating. An rpz valve is one of the safest and most reliable backflow preventer valves.
It can also be adapted with a 14 or 38 inch tubing end and with a pipe thread end just by changing the end fitting. These sturdy and reliable components are also used for seawater isolation. Class 125 200 cwp, 125 swp gate valve, threaded bonnet, solid disc, rising stem, npt. Standard detail drawings 2300 series city of scottsdale. Celcon is a registered trademark of celanese corporation.
Noncommunity systems that comply with subsection 4b of this section and the provisions of wac 51560600 of the upc which addresses the installation of backflow preventers at points of water use within the potable water system shall be considered in compliance with the requirements of this section. Controllable, reduced pressure zone backflow preventer. Backflow preventers are assemblies with two check valves and two shutoff valves that prevent reverses in process flow. Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. Backflow solutions, inc was founded with the express purpose of working with backflow professionals and water purveyors to provide exceptional backflow management solutions. Buy products related to backflow valve products and see what customers say about. Each atmospheric backflow preventer features a 38 npt female inlet and matching outlet. A backflow preventer is designed for use with irrigation systems and water pipes, preventing water from flowing back up the pipe as you might guess. Watts 34 009m3 backflow preventer reduced pressure zone assembly. Dirtmagslim dirt separator with magnet for underboiler installation.
Combinations of male and female threads are also available. What factors can cause a backpressure backflow condition. It is furnished with ball type test cocks and quarterturn, fullport bronze ball valves for shutoffs. Home plumbing backflow prevention backflow prevention collapse all. The bsi team is comprised of backflow industry professionals, with unparalleled experience and expertise in crossconnection control management. Opened and closed thumb screw a couple of times and its working correctly at. Valvcheq figure rp03 small backflow preventers emerson us. Backflow preventer lf7r 34 inch lead free bronze dual check 0072204 175psi. Backflow preventers selection guide engineering360.
S b0970fe polished chrome atmospheric back flow preventer to prevent back siphonage and back flow during continuous pressure use. Class 125 gate valve lead free, rising stem, npt 30lf series lead free bronze rs gate valve with press connections, 200 cwp, sizes. Backflow preventer parts supplying dependable backflow preventers and parts, knowledgeable sales department. Ductile iron and stainless steel npt 175 psi backflow preventer. Most backflow preventers are used to keep unsafe water from reversing flow and entering the clean water supply. Watts 34 007m3qt dual check valve, backflow preventer. Its a little hard to get excited about a backflow preventer, but this one was a good purchase. Watts 1 reduced pressure zone backflow preventor, bronze, 009qt. This 34 x 34 in lead free dual check valve prevents the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at individual outlets the valve consists of a lead free brass body construction, with two plastic replaceable check valves, and stainless steel springs. Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone. Watts number 909qt 34 npt reduced pressure backflow preventer with a double check valve assembly for nonhealth, low hazard crossconnections, and continuous pressure applications.
Means a mechanical backflow prevention device with an air inlet closed by a moving element when the device is in normal use but which opens and admits air if the water pressure upstream of the device falls to atmospheric pressure, the device being installed so that the flow of water is in a vertical downwards direction. Call 18883966202 today, our friendly and professional staff is standing by to help you find the right parts. Zurn industries llc backflow preventers cad details. They come equipped with a gauge, hoses and all required adapter fittings. The regulator is opened when the upstream pressure is at least 3psi5psi 0. Copy button triggers the copy to clipboard function, so it copies all the rows that exist in the page to your os clipboard and you can later paste it in some other software. On large assemblies 21210, the model number is located on the name plate. Backflow parts usa is a master parts distributor and we carry backflow parts and backflow devices for watts, febco, wilkins, ames, and conbraco. Backflow preventers have a variety of applications. For example, they are used to prevent boiler water, which.
Zurn 112 in lead free cast bronze double check valve assembly backflow preventer. Backpressure backflow is the reversal of normal flow in a system due to an increase in the downstream pressure above that of the supply pressure. Watts double check and reduced pressure backflow preventers. Cast copper silicon alloy fnpt 175 psi backflow preventer watts series lf007 epoxy coated cast iron flanged 175 psi backflow preventer watts series lf007 union 175 psi bronze double check valve assembly. If you wish to install your own, you must make sure that your mechanism is compatible with the water source you will be using, and that you feel. Reduced pressure zone rpz backflow preventer commercial. Most backflow preventers are mechanical devices which create a physical barrier to accomplish this. Backflow prevention products guide watts water technologies.
Flow control maximizes efficiency and prolongs the life of the system. There are 3 types of backflow protection installation methods. In turn, backflow means, water of questionable quality, wastes or other contaminants entering a public water supply system due to a reversal of flow. Kleenrite corporation watts 34 backflow preventer without. They may also include test cocks for each chamber within the assembly.
Installation of a backflow prevention device water corporation. Double check valve backflow preventers with water meter and. Discounted backflow parts including ball valves, gate valves, test kits, and brass fittings. On small assemblies 342, the model number is cast on the body. Powered by webasyst shopscript shopping cart software. Apollo valves model 40200tk3u backflow preventer test kit 3 valve the apollo valves backflow preventer test kits are compact, lightweight and portable testing devices. The type 4210rs is a check valve or backflow prevention device designed to protect nitrogen and compressed air networks against backflow from directly connected systems. The risks to drinking water quality from backflow contamination incidents pose a. Wilkins 34975xl2 34inch lead free reduced pressure backflow preventer.
Find great deals on ebay for backflow preventer and backflow preventer 34. Lay length backflow chart american backflow specialties. Backflow preventers of this type are suitable for the protection of drinking water systems. This backflow preventer quickly swaps out with the one that came with your faucet for easy use. A backflow preventer is like a oneway gate for water. Febcos backflow prevention assemblies, which prevent the backward.
313 1122 368 1245 734 73 1224 1293 345 912 679 1494 1063 1121 615 1568 1161 1557 114 642 98 204 404 700 426 1575 904 885 362 154 1577 596 1077 699 270 235 939 345 422 508 1293 1329